HOME > 제품소개 >
PDF CATEGORY GWINSTEK.jpg

LCR Meter LCR-6000 Series

모델명:
LCR-6300 / LCR-6200 / LCR-6100 / LCR-6020 / LCR-6002
특징:
▶ 테스트 주파수 : 10Hz~2kHz/20kHz/100kHz/200kHz/300kHz
▶ 기본 정확도 : 0.05%

상세설명

USBHost RS-232 Handler PCSoftware 주요 특징 10Hz~2kHz/20kHz/100kHz/200kHz/300kHz 0.05% 기본 정확도 연속적인 테스트 주파수 설정 3.5인치 컬러 LCD 측정 속도 : 최대 25ms Full/Spot 주파수 OPEN/SHORT 캘리브레이션 16개 측정 조합 + 2개 파라미터 모니터링 DCR 측정 및 내부 DC 바이어스(±2.5V) PASS/FAIL 판정 기능 ALC(Auto Level Control) 기능 BIN 기능 : 9BIN + 1AUX 10개 스텝 테스트 기능(주파수/전압/전류) RS-232C, Handler, USB(Host) 인터페이스 2U, 1/2 랙 사이즈 설계   GW Instek introduces the brand new high precision LCR meter─LCR-6000 series, which, with five models, has a test frequency range extending from 2kHz/20kHz/100kHz/200kHz/300kHz (maximum) and with 0.05% basic accuracy. The compact size design, 2U height and 1/2 rack, is one of the practical features of the series which is the optimum space saver suitable for either bench top or system rack. The compacted LCR-6000 series with abundant features is absolutely the excellent tool for R&D, production test, IQC, etc. on implementing each test stages for passive components. The LCR-6000 series provides rich functionalities with the compact size. First of all, the entire series adopts 3.5-inch color LCD and features opulent display parameters. In addition to simultaneously displaying setting criteria and measurement results, the series increases two additional monitoring parameters. In other words, there are four parameters, primary/secondary and two monitoring, simultaneously shown on the screen that tremendously enhances the measurement efficiency. The enlarge display mode not only emphasizes the measurement results, but also provides PASS/FAIL judgment to facilitate a rapid and convenient test result. Convenience is one of the unique features. The LCR-6000 series comes equipped with two zero methods, which are full frequency range and spot. Users, without turning off the power and changing test fixture, can freely change frequency within the provided frequency range to conduct measurements. By so doing, tremendous time can be saved from repeatedly executing zero operation. Additionally, frequency range of the series is consecutive that allows users to input precise frequency value to conduct the most genuine test on components. The LCR-6000 series also features diverse ancillary measurements to meet the measurement requirements of different materials. For instance, the series provides the automatic level control (ALC) function to satisfy the test voltage requirement of MLCC. For inductive component measurements, the series provides the adjustable test current function and the D.C. resistance measurement function. The optional external bias current adapter (±2.5A) is to satisfy the measurement requirements. With respect to the D.C. bias voltage test for capacitive components requirements, the series allows users to conduct verification measurement on materials by its internal ±2.5V adjustable voltage or via an optional external bias voltage adapter (±45V). Furthermore, 10 steps of listed test functionalities allow users to set testing parameters (either by frequency, or voltage, or current) for each step based on users’ requirements in order to observe the trend of DUT characteristics. The LCR-6000 series has 10 memory sets defined by panel setting criteria to facilitate users in selecting test criteria and saving time in repeated settings. 10,000 measurement result storage capability can easily record measurement results instantaneously. The USB host allows easy access to recorded results without connecting the series to the PC. The USB host also allows USB to retrieve and save screen so as to assist users in compiling setting guidelines. For the external control, the LCR-6000 series provides handler interface and collocates with its measurement sorting function (9BIN, AUX: 1BIN) to facilitate the connection with sorting machine so as to sort out the materials. For remote control and measurement result retrieval requirements, the LCR-6000 series provides RS-232Cto assist setting control or measurement result retrieval via the PC commands. Additionally, the free PC software gives users an instant tool to store measurement results that saves time in developing programs. The brand new compacted LCR-6000 series can effectively improve the limitation of space. Diverse measurement functionalities and display methods are making the series the high CP ratio choice in meeting the requirements of R&D, component assessment for engineering departments, category sorting requirements for component production, and IQC for verification on component specifications. Consecutive frequency and Convenient zero function The LCR-6000 series, within the provided frequency range, features consecutive and adjustable frequency capability which allows users to conduct measurement and analysis on components with the most genuine frequency requirements. For OPEN/SHORT fixture compensation function, the LCR-6000 series is equipped with full frequency range zero and spot zero selections. After executing full frequency range zero, users, under the conditions of not turning off the power and not changing test fixture, can freely change test frequency for the LCR-6000 series to execute component measurements that tremendously saves time in repeatedly zeroing test fixture after changing frequency. Consecutive and adjustable frequency Freely input frequency within provided frequency range Selectable fixture zeroing methods Full frequency range zero or spot zero Rich and diverse information display The measurement result display of the LCR-6000 series not only reveals primary and secondary measurement parameters but also includes two monitoring parameters. Therefore, four DUT related parameters can be simultaneously shown on the display screen to save time if repeated measurements are required. With respect to display screen, the LCR-6000 series features diverse display to meet users’ observation requirements. For instance, MEAS display shows setting parameters and measurement results at the same time; ENLARGE display focuses on measurement results and PASS/FAIL judgment is available, which is conducive to assist engineers to swiftly obtain the validity of measurement results. MEAS displayParameter setting and four measurement parameters ENLARGE displayEnlarge measurement results and include PASS/FAIL judgment 10 points listed tests and PC software The LCR-6000 series provides the 10 points listed test function, which allows users to define a set of DUT measurement parameters (such as Cs- Rs) and to set 10 test criteria of category (either by frequency or by voltage or by current) but different values to conduct measurements. Through this function, users can rapidly and clearly obtain DUT’s characteristic variation trend to determine the adaptability of DUT’s practical applications. The measurement results can be recorded directly in the internal memory and be transferred to the PC through USB. The LCR-6000 series also provides free PC software (maximum 1,000 points listed tests) in order to satisfy users’ analytical requirements on delicate variation. Listed testsVariation criteria based upon frequency or voltage/current On software ─ characteristic curveProvide more delicate characteristic variation trend Diverse ancillary measurement functions To satisfy the diverse measurement application requirements for different components and materials, the LCR-6000 series collocates with many auxiliary measurement functions. For capacitor measurement, Automatic Level Control (ALC) is mainly for component which requires a constant or rated test voltage such as multi-layer ceramic capacitor (MLCC). An internal D.C. bias voltage (±2.5V, internal) is allowing simulating A.C. and D.C. coexistence to learn capacitance variation. For inductor measurement, the D.C. resistance measurement function is to validate D.C. resistance characteristics. Additional, the LCZ function is to quickly identify components ’characteristics. When the function is activated, the LCR-6000 series will automatically determine DUTs’ characteristics and reveal the optimum parameters to show the measurement results. Automatic level controlIdeal for measuring components with voltage requirements Internal bias (±2.5V adjustable)Ideal for capacitive components’ characteristic tests D.C. resistance measurementIdeal for inductive components’ D.C. characteristics verification Standard Interface For interface connectivity, the LCR-6000 series comes equipped with handler interface and RS-232C interface. Handler outputs 10 BIN (9BIN, AUX: 1BIN) sorting results that is best for external connection control, for instance, connecting to a sorting machine to conduct components’ sorting operation. RS-232C is suitable for remote control and measurement results retrieval. The PC gives commands to control settings or to read measurement results so as to achieve the requirements of verifying automotive applications.   TEST FREQUENCY LCR-6300: 10Hz~300kHz(±0.01%) (4 digits resolution)LCR-6200: 10Hz~200kHz(±0.01%) (4 digits resolution)LCR-6100: 10Hz~100kHz(±0.01%) (4 digits resolution)LCR-6020: 10Hz~ 20kHz(±0.01%) (4 digits resolution)LCR-6002: 10Hz~ 2kHz(±0.01%) (4 digits resolution) OUTPUT IMPEDANCE 30Ω / 50Ω / 100Ω selectable BASIC ACCURACY Slow / Med 0.05% Fast 0.1% TEST SPEED FAST:25ms / MED:100ms / SLOW:333ms TEST SIGNAL LEVELS Voltage 10.00mV- 2.00V (±10%) CV :10.00mV- 2.00V(±6%) Current 100.0uA- 20.00mA (±10%) CC :100.0uA- 20.00mA(±6%) (@2VMax) DC BIAS Internal ±2.5V (0.5%+0.005V) DISPLAYRANGE R, X, |Z| G, B, |Y| L C D Q θd θr DCR Δ% 0.00001Ω ~ 99.9999MΩ 0.01nS ~ 999.999S 0.00001uH ~ 9999.99H 0.00001pF ~ 9999.99mF 0.00001 ~ 9.99999 0.00001 ~ 99999.9 -179.999° ~ 179.999° -3.14159 ~ 3.14159 0.00001Ω ~ 99.9999MΩ -99999% ~ 99999% TEST MODE 16 Combinations Cs-Rs, Cs-D, Cp-Rp, Cp-D, Lp-Rp, Lp-Q, Ls-Rs, Ls-Q,Rs-Q, Rp-Q, R-X, Z-θr, Z-θd, Z-D, Z-Q, DCR Monitor parameter (2 selectable) Z, D, Q, Vac, Iac, Δ, Δ%, θr, θd, R, X, G, B, Y LISTED MODE 10 steps BIN FUNCTION Comparator (9BIN,AUX:1BIN) MEMORY INT ? panel setting 10 file name INT ? measured data 10000 Data(.csv) USB storage 10 file name for setting, 9999 file name for data, 999 Log file for LCD screen OTHER FUNCTION Auto Level Control (ALC) ON/OFF Average 1~256 times Trigger INT / MAN / EXT / BUS Delay 0ms~60s Judgment PASS / FAIL Auto LCZ ON / OFF Screen Capture Saving in to USB (Bmp form) DISPLAY 3.5'LCD, RGB color (320x240) INTERFACE RS-232(SCPI), Handler, USB Host POWER SOURCE AC 90V-250V, 50-60Hz, Max. 30VA DIMENSION & WEIGHT 265(W)x107(H)x312(D) mm, Approx.3kg 상세설명 (Description)scription) 사양 (Specification) 악세사리 (Accessories) 주문정보 (Ordering Information) 기본 악세사리 옵션 악세사리 Safety Sheet x 1 Power Cord x 1 LCR-06A x 1 CD x 1(User manual / PC software) LCR-05, Test Fixture for Axial & Radial Lead Components LCR-06A, Kelvin Clip Test Lead LCR-07, Test Fixture, Two-Wire with Alligator Clips LCR-08, Test Fixture (Tweezers) for SMD/Chip Components LCR-15, Test Fixture for SMD/Chip Components (0201 to 1812) LCR-16, Test Fixture ? ±45V DC Bias Voltage Box LCR-17, Test Fixture ? ±2.5ADC Bias Current Box GTL-232, RS-232C Cable, 9-pin Female to 9-pin, null Modem for Computer, Approx.2m 상세설명 (Description) 사양 (Specification) 악세사리 (Accessories) 주문정보 (Ordering Information) 본체 (제품 가격은 사전 공지없이 변경될 수 있습니다) 품목 설명 가격 (VAT 별도) LCR-6300 300kHz 고정밀 LCR 미터 3,155,000원 LCR-6200 200kHz 고정밀 LCR 미터 2,783,000원 LCR-6100 100kHz 고정밀 LCR 미터 2,455,000원 LCR-6020 20kHz 고정밀 LCR 미터 2,088,000원 LCR-6002 2kHz 고정밀 LCR 미터 1,375,000원 옵션 및 악세사리 (제품 가격은 사전 공지없이 변경될 수 있습니다) 품목 설명 가격 (VAT 별도) LCR-15 SMD/칩 부품 테스트 픽스쳐 (0201~1812) 280,000원 LCR-16 테스트 픽스쳐 (±45V DC 바이어스 전압 박스) 712,000원 LCR-17 테스트 픽스쳐 (±2.5A DC 바이어스 전류 박스) 398,000원
목록보기